The protocol converters of the CPE family have been designed to connect Hyterm regulators to the most widespread communication networks and field buses for building and industrial automation on the market.
The Plug & Play connection to the FC family regulators requires no programming or initial parameterization, simplifying machine start-up.
Made in standard small and compact enclosures, they mount on DIN rail allowing installation in limited spaces.
| TECHNICAL DATA | |
|---|---|
| Nominal voltage: | 8÷24Vac 50/60Hz o 12÷35Vdc |
| Power consumption: | 5VA |
| Electrical connections: | Removable screw terminal block pitch 5.08 (Power supply) |
| Cable section: | min 0.5 mmq ÷ max 2.5 mmq / min 20 AWG Cu ÷ max 14 AWG Cu |
| OPERATING CONDITIONS | |
|---|---|
| Operating temperature: | -40÷85°C – max Rh 85% non-condensing |
| Storage temperature: | -40÷85°C – max Rh 85% non-condensing |
| Vibrations: | less than 1g (9.8m/s²) |
| Degree of protection: | IP20 |
| Insulation class: | Triple insulation between power supply, insulation, and communication ports |
| PROTOCOLS | |
|---|---|
| MODBUS RTU RS485 vs: |
|
| ENCLOSURE | |
|---|---|
| Mounting: | on DIN rail according to DIN 43880 CEI EN 50022 |
| Material: | PC / ABS |
| Self-extinguishing: | V0 - 5VB (according to UL94) |
| GWFI: | 960°C (according to IEC 60695-2-12) |
| Color: | Grey RAL 7035 |
| DIMENSIONS | |
|---|---|
| Dimensions: |
A1: 23 x 101 x 120 mm A2: 71 x 95 x 60 mm |
| Weight: | 200g |
| STANDARDS | |
|---|---|
| Compliance: | 2014/30/EU (EMC – Electromagnetic Compatibility) |
| Reference standards: | EN 61000-6-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11, ENV 50204 |


| PRODUCT CODES | |
|---|---|
| 12.001.00.0000 | CPE100 - Enclosure A1 - BACnet IP Slave - MODBUS RTU RS485 |
| 12.001.00.0001 | CPE101 - Enclosure A1 - BACnet MSTP Slave - MODBUS RTU RS485 |
| 12.001.00.0002 | CPE102 - Enclosure A1 - PROFINET - MODBUS RTU RS485 |
| 12.001.00.0003 | CPE103 - Enclosure A1 - PROFIBUS DP Slave - MODBUS RTU RS485 |
| 12.001.00.0004 | CPE104 - Enclosure A1 - MODBUS TCP Slave - MODBUS RTU RS485 |
| 12.001.00.0005 | CPE105 - Enclosure A1 - Ethernet - MODBUS RTU RS485 |
| 12.001.00.0006 | CPE106 - Enclosure A1 - Ethernet/IP - MODBUS RTU RS485 |
| 12.001.00.0007 | CPE107 - Enclosure A2 - KNX Converter - MODBUS RTU RS485 |
| 12.001.00.0008 | CPE108 - Enclosure A1 - SNMP Agent Converter - MODBUS RTU RS485 |
| TYPE | DOWNLOADABLE DOCUMENT | DATE |
|---|---|---|
| Technical Data Sheet | 29/09/2021 | |
| BACnet Protocol FC400 | 03/03/2025 | |
| CPE100 Manual (BACNet) | 28/10/2025 | |
| SWCPE10X Program (BACNet) | 28/10/2025 | |
| PROFINET Protocol FC400 | 03/03/2025 | |
| CPE102 Manual (PROFINET) | 28/10/2025 | |
| SWCPE102 Program (PROFINET) | 28/10/2025 | |
| PROFIBUS DP Protocol FC400 | 03/03/2025 | |
| CPE103 Manual (PROFIBUS DP) | 28/10/2025 | |
| SWCPE103 Program (PROFIBUS DP) | 28/10/2025 | |
| Mechanical drawing | 25/01/2023 |